Search results for "particle accelerators"
showing 10 items of 22 documents
Mechanisms of Electron-Induced Single-Event Upsets in Medical and Experimental Linacs
2018
In this paper, we perform an in-depth analysis of the single-event effects observed during testing at medical electron linacs and an experimental high-energy electron linac. For electron irradiations, the medical linacs are most commonly used due to their availability and flexibility. Whereas previous efforts were made to characterize the cross sections at higher energies, where the nuclear interaction cross section is higher, the focus of this paper is on the complete overview of relevant electron energies. Irradiations at an electron linac were made with two different devices, with a large difference in feature size. The irradiations at an experimental linac were performed with varying en…
Hippocampal dose during Linac-based stereotactic radiotherapy for brain metastases: An observational study
2017
Abstract Introduction Aim of the present study is to evaluate homolateral and contralateral hippocampus (H-H, C-H, respectively) dose during Fractionated Stereotactic Radiotherapy (FSRT) or Radiosurgery (SRS) for brain metastases (BM). Materials & methods Patients with BM 3 months, were considered for SRS/FSRT (total dose 15–30 Gy, 1–5 fractions). For each BM, a Flattening Filter Free (FFF) Volumetric Modulated Arc Therapy (VMAT) plan was generated with one or two arcs. Hippocampi were not considered during optimizations phase and were contoured and evaluated retrospectively in terms of dose: the Dmedian, Dmean, D0.1cc and the V1Gy, V2Gy, V5Gy and V10Gy were analyzed. Results From April 2…
Precision luminosity measurements at LHCb
2014
Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy $\sqrt{s}$. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for $\sqrt{s}$ = 2.76, 7 and 8 TeV (proton-proton collisions) and for $\sqrt{s_{NN}}$ = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves sig…
Detector for monitoring potential bleeding during electron intraoperative radiotherapy
2018
Purpose: The aim of this work is to develop a bleeding detector integrated into the acrylic circular applicators for specific mobile linacs. Thus, a bleeding detector has been developed based on a capacitive sensor to be used with plastic applicators, as in the case of LIAC HWL from Sordina IORT Technologies SpA. According to the clinical impact, we have selected 0.5 cm as the minimum depth of fluid that should be detected. Methods: An experiment was developed using water-simulating blood. Two setups were considered: non-beveled applicators with 7 cm and 10 cm diameter. Measurements were done for applicators 0 degrees and 45 degrees tilted, both with respect to the horizontal surface, in or…
Phantom development for daily checks in electron intraoperative radiotherapy with a mobile linac.
2020
Abstract Purpose IORT with mobile linear accelerators is a well-established modality where the dose rate and, therefore, the dose per pulse are very high. The constancy of the dosimetric parameters of the accelerator has to be checked daily. The aim of this work is to develop a phantom with embedded detectors to improve both accuracy and efficiency in the daily test of an IORT linac at the surgery room. Methods The developed phantom is manufactured with transparent polymethyl methacrylate (PMMA), allocating 6 parallel-plate chambers: a central one to evaluate the on-axis beam output, another on-axis one placed at a fixed depth under the previous one to evaluate the energy constancy and four…
PERIPHERAL SURFACE DOSE FROM A LINEAR ACCELERATOR: RADIOCHROMIC FILM EXPERIMENTAL MEASUREMENTS OF FLATTENING FILTER FREE VERSUS FLATTENED BEAMS
2020
Abstract There is a growing interest in the use of flattening filter free (FFF) beams due to the shorter treatment times. The reduction of head scatter suggests a better radiation protection to radiotherapy patients, considering the expected decrease in peripheral surface dose (PSD). In this work, PSD of flattened (FF) and FFF-photon beams was compared. A radiochromic film calibration method to reduce energy dependence was used. PSD was measured at distances from 2 to 50 cm to the field border for different square field sizes, modifying relevant clinical parameters. Also, clinical breast and prostate stereotactic body radiotherapy (SBRT) plans were studied. For square beams, FFF PSD is lowe…
Improving bleeding detector features for electron intraoperative radiotherapy
2019
Abstract Purpose The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been develope…
Mechanisms of Electron-Induced Single-Event Latchup
2019
In this paper, possible mechanisms by which electrons can induce single-event latchups in electronics are discussed. The energy deposition and the nuclear fragments created by electrons in silicon are analyzed in this context. The cross section enhancement effect in the presence of high-Z materials is discussed. First experimental results of electron-induced latchups are shown in static random access memory devices with low linear energy transfer thresholds. The radiation hardness assurance implications and future work are discussed.
Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
2009
Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…
Innovative remotely-controlled bending device for thin silicon and germanium crystals
2020
Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).